Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Level
IN
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define the various basic tim-
ers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Input Data
Layer 3 Timer Type Number 1 ~ 5
Item No. Item Description Input Data Default
01 T301 Specifies the timer value in 1/100ths of a
second of the timer to be started when the
ALERT message is received.
0, 180 ~ 254 seconds 180 seconds
02 T302 Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is sent. Timer is also restarted
when INFO is received.
1 ~ 254 seconds 15 seconds
03 T303 Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent.
1 ~ 254 seconds 4 seconds
04 T304 Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is received. Timer is also re-
started when INFO is received.
0 ~ 254 seconds 30 seconds
05 T305 Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC without progress No. 8 is sent.
1 ~ 254 seconds 30 seconds
06 T306 Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC with progress indicator No. 8 is sent.
This timer is valid for Network side use
only.
0 ~ 254 seconds 30 seconds
07 T307 Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND ACK is sent. This timer is valid
only for Network side use only.
1 ~ 254 seconds 180 seconds
08 T308 Specifies the timer value in 1/100ths of a
second of the timer to be started when
REL is sent.
1 ~ 254 seconds 4 seconds
09 T309 Specifies the timer value in 1/100ths of a
second upon data link disconnection.
1 ~ 254 seconds 90 seconds
10 T310 Specifies the timer value in 1/100ths of a
second of the timer to be started when
CALL PROC is sent.
0 ~ 180 seconds 180 seconds
11 T312 Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent or re-sent on broadcast
data link. This timer is only valid for Net-
work side use only.
1 ~ 254 seconds 6 seconds
12 T313 Specifies the timer value in 1/100ths of a
second of the timer to be started when
connection request is sent. Valid range 1 ~
4 seconds in 1 second increments. Value
of 0 indicates timer not used.
1 ~ 254 seconds 4 seconds
ISSUE 1.0SL1000/SL1100
Program
81