Program 22 : Incoming Call Setup
22-09 : DID Basic Data Setup
Level
IN
Description
Use Program 22-09 : DID Basic Data Setup to define the basic setting of Dial-In incoming calls for
each trunk group.
Input Data
Trunk Group Number 01 ~ 25
Item No. Item Input Data Default
01 Expected Number of Digits
Enter the number of digits the
table expects to receive from the
Telco. Use this program to make
the system compatible with 3-
and 4-digit DID service. If ISDN
trunks, we analyze the last digits
that are set here. If it is T-1 or
analog DID, it analyzes the first
digits that are assigned here.
1~8 2
02 Received Vacant Number Op-
eration
Use this option to enable or dis-
able Vacant Number Intercept.
0 = Disconnect (Cut)
1 = Transfer (Refer to
Program 22-12 : DID In-
tercept Ring Group. on page 2-258)
0
03 Sub-Addressing Mode 0 = Extension # Specify (Intercom)
1 = DID Conversion Table
0
04 DID Receiving Mode for ISDN 0 = Enbloc Receiving
1 = Overlap Receiving
0
05 Local Code Digits
(Only Overlap Receiving Mode)
0 ~ 15 (0 = No Local Code) 0
06 Local Code
(Only Overlap Receiving Mode)
Dial (maximum 16 digits) No setting
07 Pilot Code
(Only Overlap Receiving Mode)
Dial(1digit:0~9) Nosetting
08 T302 Time-out Operation
(Only Overlap Receiving Mode)
0 = Disconnect (Cut)
1 = Transfer (Refer to
Program 22-12 : DID In-
tercept Ring Group. on page 2-258
)
2 = Search
0
Conditions
None
Feature Cross Reference
Direct Inward Dialing (DID)
ISSUE 1.0 SL1000/SL1100
Program
22
Programming Manual 2-253