Program 90 : Maintenance Program
90-10 : System Alarm Setup
Level
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate
an alarm as Major or Minor. This program also assigns whether or not the alarm information is reported
to the pre-defined destination.
Input Data
Alarm Number 001 ~ 100
Item No. Item Input Data
01 Alarm Type 0 = Not Set
1 = Major Alarm
2 = Minor Alarm
02 Report 0 = Not Report (No autodial)
1 = Report (autodial)
Table 2-18 Description of Alarm
Alarm
No.
Type
Re-
port
Name
Content of
Alarm
Cause Action Recovery
Alarm
Status
1 2 0 PKG Initial-
ize Error.
1 The PKG failed
to initialize.
2 The PKG did
not start nor-
mally.
1 PKG not in-
serted firmly.
2 PKG was re-
moved, but not
reinserted
firmly.
3 Old PKG data
still reported
due to no ini-
tialization.
1 Insert PKG
firmly.
2 Insert PKG
firmly.
3 Delete slot in-
formation in
Program 90-05
and insert the
PKG again.
During ini-
tialization,
the PKG is
recognized.
ERR
REC
2 2 0 PKG
Mounting
Error
The unit did not
step on a regular
procedure and it
was pulled out.
Or, it is not normally
inserted.
1 The package is
not completely
inserted.
2 The package is
out of order.
1 Please insert
the package
firmly.
2 Please try again
after initializing
the system data
once when LED
doesn't blink
normally.
3 Exchange pack-
ages.
When unit is
reconfirmed,
the error is
recovered.
ERR
REC
ISSUE 1.0 SL1000/SL1100
Program
90
Programming Manual 2-511