EasyManua.ls Logo

NEC SL1000 - MFC Tone Setup

NEC SL1000
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 80 : Basic Hardware Setup for System
80-08 : MFC Tone Setup
Level
IN
Description
Use Program 80-08 : MFC Tone Setup to define the duration (On time) and pause (Off time) for MFC
dialing. This option affects all trunk line calls system wide. And also it is possible to adjust the level of
tone.
Input Data
Item No. Item Input Data Default
01 Duration (On time) 1 ~ 255 (20 ms ~ 5100 ms) 5 (100 ms)
02 Pause (Off time) 1 ~ 255 (20 ms ~ 5100 ms) 5 (100 ms)
03 Tone Level 1~97(-45dB~+3dB) 77(-7dB)
Duration
Pause
Conditions
None
Feature Cross Reference
None
ISSUE 1.0SL1000/SL1100
Program
80
Program 80 : Basic Hardware Setup for System2-432

Table of Contents

Other manuals for NEC SL1000

Related product manuals