Loading...
Program 10 : System Configuration Setup
10-23 : SIP System Interconnection Setup
Level
SA
Description
Use Program 10-23 : SIP System Interconnection Setup to determine if the system is intercon-
nected and define the IP address of another system, call control port number and alias address for
SL1000/SL1100 system interconnection.
Input Data
System Number 001 ~ 1000
Item No. Item Input Data Default
01 System
Interconnection
0 = No (Disable)
1 = Yes (Enable)
0
02 IP Address 0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0
03 Call Control Port 1 ~ 65535 1720
04 Dial Number Up to 12 digits (0 ~ 9) Not Set
Conditions
None
Feature Cross Reference