Program 10 : System Configuration Setup
10-12 : CPU Network Setup
Level
SA
Description
Use Program 10-12 : CPU Network Setup to setup the IP Address, Subnet-Mask, and Default Gate-
way addresses.
Caution! If any IP Address or NIC settings are changed, the system must be reset for the
changes to take affect.
Input Data
Item
No.
Item Input Data Default Description
01 IP Address 0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
192.168.0.10 Set for CPU.
02 Subnet Mask 128.0.0.0
240.0.0.0
254.0.0.0
255.192.0.0
255.248.0.0
255.255.0.0
255.255.224.0
255.255.252.0
255.255.255.128
255.255.255.240
255.255.255.254
192.0.0.0
248.0.0.0
255.0.0.0
255.224.0.0
255.252.0.0
255.255.128.0
255.255.240.0
255.255.254.0
255.255.255.192
255.255.255.248
255.255.255.255
224.0.0.0
252.0.0.0
255.128.0.0
255.240.0.0
255.254.0.0
255.255.192.0
255.255.248.0
255.255.255.0
255.255.255.224
255.255.255.252
255.255.255.0 The setting of
Subnet Mask
is invalid when
all Host Ad-
dresses are 0.
If the network
section is:
0,
127,
128.0,
191.255,
192.0.0,
223.255.255
The setting of
Subnet Mask
is invalid.
03 Default
Gateway
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
0.0.0.0 IP Address for
Router.
04 Time Zone 0~24 (0 = -12 Hours and 24 = +12 Hours) 12 Determine the
offset from
Greenwich
Mean Time
(GMT) time.
Then enter its
respective
value.
For example,
Eastern Time
(US and
Canada) has a
GMT offset of
-5.
The program
data would
then be 7
(0=-12,
1=-11,
2=-10,
3=-9,
4=-8,
5=-7,
6=-6,
7=-5,
:
24 = + 12)