Program 22 : Incoming Call Setup
22-02 : Incoming Call Trunk Setup
Level
IN
Description
Use Program 22-02 : Incoming Call Trunk Setup to assign the incoming trunk type for each trunk.
There is one item for each Night Service Mode.
Input Data
Trunk Port Number 001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Item
No.
Day/Night
Mode
Incoming Type Default Description
Related Pro-
gram
01 1 ~ 8 0 = Normal
1 = VRS (second dial tone if
no VRS installed)
2=DISA
3=DID
4=DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID (DDI) Mode Switch-
ing
0 Use this option to set the feature type
for the trunk you are programming.
14-04
Conditions
When connecting to T1 trunks, after changing Program 22-02-01 to match the Telco connected T1
service type, the T1 cable or the T1 unit must be unplugged and then reconnected for the T1 unit to
sync.
When the trunk type is set to 3 (DID), the DID Transfer to Destination in 22-11-04 for each DID fea-
ture is not supported. This feature is supported only for DID trunks when assigned as VRS.
When the trunk type is set to 3 (DID), the DID Intercept Destination feature for each DID is not sup-
ported. This feature is supported only for DID trunks assigned as VRS.
Feature Cross Reference
Central Office Calls, Answering
ISSUE 1.0 SL1000/SL1100
Program
22
Programming Manual 2-245