Program 20 : System Option Setup
20-15 : Ring Cycle Setup
Level
IN
Description
Use Program 20-15 : Ring Cycle Setup to define the ringing cycles for each ring type.
Input Data
Item No. Incoming Signal Type Ringing Cycle Default
01 Normal Incoming Call on Trunk
1~13
3
02 PBX, CES Incoming Call 8
03 Incoming Internal Call 8
04 DID/DISA/VRS 8
05 DID/DDI 8
06 Dial-In in the E&M Tie Line 8
07 Door Box Ringing for SLT 2
08 Virtual Extension Ring 8
09 Callback 4
10 Alarm for SLT 5
11 VRS Waiting Message Incoming Call 6
Table 2-4 Ringing Cycles
Number Ringing Cycle
1On
2 On:2.0/Off:4.0
3 On:1.0/Off:2.0
4 On:0.5/Off:0.5
5 On:0.25/Off:0.25
6 On:0.5/Off:0.5/On:0.5/Off:1.5
7 On:0.25/Off:0.25/On:0.25/Off:5.25
8 On:0.375/Off:0.25/On:0.375/Off:2.0
9 On:0.25/Off:0.125/On:0.25/Off:0.125/On:0.25/Off:2.0
10 On:1.0/Off:4.0
11 On:0.25/Off:0.25/On:0.25/Off:4.25
12 On:1.0/Off:3.0
13 On:0.25/Off:0.25/On:0.25/Off:2.25
Conditions
None