Program 20 : System Option Setup
20-18 : Service Tone Timers
Level
IN
Description
Use Program 20-18 : Service Tone Timers to set the values for the system service tone timers. Refer
to the following chart for a description of each option, its range and default setting.
Input Data
Item
No.
Item Input Data Default Description
Related Pro-
gram
01 Extension Dial Tone Time 0 ~ 64800 seconds 30 After getting Intercom dial
tone, a telephone user has
this time to dial the first
digit of the Intercom call.
02 Busy Tone Timer 0 ~ 64800 seconds 15
03 Congestion Tone 0 ~ 64800 seconds 10 A Busy Tone when system
resources run short. (Such
as DTMF receiver re-
sources).
04 Call Waiting Tone Timer 0 ~ 64800 seconds 10 This option sets the time
between Call Waiting
tones. This timer also sets
the time between Off-Hook
Signaling alerts.
05 Multiline Confirmation
Tone
0 ~ 64800 seconds 10
06 Interval of Call Waiting
Tone
0 ~ 64800 seconds 10
07 Intrusion Tone Repeat
Time
0 ~ 64800 seconds 0 After a call is interrupted
(such as Barge-In, Voice
Mail Conversation Record-
ing, or Voice Over), the
system repeats the Intru-
sion Tone after this time.
Normally, you should enter
0 to disable this time.
08 Conference Tone Interval 0 ~ 64800 seconds 0
09 Warning Beep Tone Sig-
naling Interval
0 ~ 64800 seconds 60 14-01-18