Program 22 : Incoming Call Setup
22-01 : System Options for Incoming Calls
Level
IN
Description
Use Program 22-01 : System Options for Incoming Calls to define the system options for incoming
calls.
Input Data
Item No. Item Input Data Default Related Program
01 Incoming Call Priority
Use this option to determine if Inter-
com calls or trunk calls have answer
priority when both are ringing simulta-
neously.
0 = Intercom Call Priority
1 = Trunk Call Priority
1 15-02-22
02 Incoming Call Ring No Answer
Alarm
If enabled, an incoming call that rings
longer than the Ring No Answer
Alarm interval (22-01-03), changes to
a unique ring cadence to indicate that
the call has been ringing too long. If
disabled, this does not occur.
0 = Disable (Off)
1 = Enable (On)
0 22-01-03
22-01-04
03 Ring No Answer Alarm Time
If a trunk rings a multiline telephone
longer than this interval, the system
changes the ring cadence. This indi-
cates to the user that the call has
been ringing too long.
0 ~ 64800 seconds 60 seconds 22-01-02
04 DIL No Answer Recall Time
A DIL that rings its programmed des-
tination longer than this interval di-
verts to the DIL No Answer Ring
Group (set in Program 22-08).
0 ~ 64800 seconds 0 second
06 DID Ring-No-Answer Time
In systems with DID Ring-No-Answer
Intercept, this sets the Ring-No-
Answer time. This time is how long a
DID call rings the destination exten-
sion before rerouting to the intercept
ring group.
0 ~ 64800 seconds 20 seconds 22-12
07 DID Incoming Ring Group No An-
swer Time
0 ~ 64800 seconds 20 seconds
08 DID Pilot Call No Answer Time 0 ~ 64800 seconds 60 seconds
09 DID to Trunk to Trunk no answer
timer
0 ~ 64800 seconds 20 seconds
10 VRS Waiting Message Operation
Set up the operation mode for Auto
Attendant and Queuing Message.
0 = Enable Always
1 = Change by Manual Op-
eration
0 22-14
22-15
22-08
22-04
22-01-04
20-15-11
15-07
11 VRS Waiting Message Interval
Time
Setup the sending duration time of
the Auto - Attendant & Queuing.
The message is repeatedly sent out
during the specified time.
0 ~ 64800 seconds 20 seconds 22-14-06
22-15-06
41-11-06
ISSUE 1.0 SL1000/SL1100
Program
22
Programming Manual 2-243