Program 20 : System Option Setup
20-46 : Security Sensor Setup
Level
IN
Description
Use Program 20-46 : Security Sensor Setup to defines the security sensor.
Input Data
Security Sensor Number 1~8(SL1000)
1~6(SL1100)
Item No. Item Input Data Default
01 Sensor Mode
Define door port (408M 6, 7 (SL1000) 084M 3, 4 (SL1100)) to
use as Sensor.
0=Off
1=On
0
02 Internal Paging Group for Warning Message
Define Internal paging group number for Warning message
0~32 0
03 Ring Timer
Define External paging group number for Warning message.
0~8 0
04 VRS Message for Warning
Define VRS number used for Warning message.
0 ~ 100 0
05 Auto Dial Number Area Setting
Define Speed dial number when sensor detects warning.
0 ~ 999 0
06 VRS Message for Answer
Define VRS message number when emergency call destina-
tion answered.
0 ~ 100 0
07 Auto Dial Wait Timer
Define wait time before making emergency auto dial.
0 ~ 64800 30
08 Time of Repeat Auto Dial
Define repeat number for making emergency call.
0 ~ 255 3
09 Auto Dial Calling Time
Define calling continue time when making emergency call.
0 ~ 64800 30
10 Monitored Terminal
Define extension number for monitor from outside. IP terminal
cannot set as monitored extension.
Extension Number (Up
to 4 digits) (SL1000)
Extension Number (Up
to 8 digits) (SL1100)
No setting
11 Interval of Auto Dial 0 ~ 3600 0