Program 81 : Basic Hardware Setup for Trunk
81-01 : CO Initial Data Setup
Level
IN
Description
Use Program 81-01 : CO Initial Data Setup to define the various basic data parameters for the COIU.
Input Data
Item No. Item Input Data Default Note
01 PCM Encoding Method Specifica-
tion
0 = μ-law
1 = A-law
1 (A-law)
02 Loop Current Detection Time 1 ~ 255
(10 ~ 2550 ms)
60 (600 ms)
03 Clear Signal (Open Loop) Detec-
tion Time
1 ~ 255
(5 ~ 1275 ms)
59 (295 ms)
04 Ringing Signal Detection Mini-
mum Time
1 ~ 255
(10 ~ 2550 ms)
10 (100 ms)
05 Single Ringing Detection Mini-
mum Time
0 ~ 255
(0, 10 ~ 2550 ms)
66 (660 ms)
06 Double Ringing Detection Mini-
mum Off Time
0 ~ 255
(0, 10 ~ 2550 ms)
10 (100 ms)
07 Double Ringing Detection Maxi-
mum Off Time
0 ~ 255
(0, 10 ~ 2550 ms)
40 (400 ms)
08 Ringing Signal not Detection
Minimum
1 ~ 255
(10 ~ 2550 ms)
70 (700 ms)
09 Time Ringing Signal Stop Detec-
tion Time
1 ~ 255
(100 ~ 25500 ms)
50 (5000 ms)
10 Continuous Ringing Minimum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
30 (300 ms)
11 Continuous Ringing Maximum
Time
0 ~ 255
(0, 10 ~ 2550 ms)
70 (700 ms)
14 Hook Flash 1 Time 1 ~ 255
(10 ~ 2550 ms)
80 (800 ms)
15 Hook Flash 2 Time 1 ~ 255
(100 ~ 25500 ms)
25 (2500 ms)
16 Pause Time 1 ~ 255
(100 ~ 25500 ms)
30 (3000 ms)
17 PFT Idle Detection Time 1 ~ 255
(100 ~ 25500 ms)
30 (3000 ms)
20 Loop Reverse Detect Minimum
Time
1 ~ 255
(10 ~ 2550 ms)
10 (100 ms)
21 Loop Reverse Detect Maximum
Time
1 ~ 255
(10 ~ 2550 ms)
86 (860 ms)
22 Loop Disconnect Detect Mini-
mum Time
1 ~ 255
(10 ~ 2550 ms)
50 (500 ms)
23 Loop Disconnect Detect Maxi-
mum Time
1 ~ 255
(10 ~ 2550 ms)
70 (700 ms)
27 Dial Pulse Break Time (10pps) 1 ~ 255
(5 ~ 1275 ms)
13 (65 ms)
ISSUE 1.0SL1000/SL1100
Program
81
Program 81 : Basic Hardware Setup for Trunk2-438