Program 22 : Incoming Call Setup
22-17 : Dial-In Conversion Table Area Setup for Time
Pattern
Level
SA
Description
Use Program 22-17: Dial-In Conversion Table Area Setup for Time Pattern to define Time Zone
and Dial-In Conversion Table (Program 22-11) for Time Pattern.
Input Data
Conversion Table Number 001 ~ 100
Time Pattern Number 1 ~ 8
Item No. Item Input Data Default
01 Received Dial Up to eight digits No setting
02 Start of Time 0000 ~ 2359 (Time) 0000
03 End of Time 0000 ~ 2359 (Time) 0000
04 Dial-In Conversion Table Number 0 ~ 800 0
Conditions
None
Feature Cross Reference
None
ISSUE 1.0 SL1000/SL1100
Program
22
Programming Manual 2-263