Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
Level
IN
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is de-
fined by the combination of 32 Basic Tones.
Input Data
Service Tone Number 01 ~ 64
Item No. Item Input Data
01 Repeat Count 0 ~ 255 (0 = Endless)
Unit Number 1 ~ 8
Item No. Item Input Data
02 Basic Tone Number 0~33
(0 = No Tone)
(33 = Default Time Slot)
03 Duration Count 0 ~ 255 (0, 100 ~ 25500 ms)
04 Gain Level (dB) 0~63(-15.5~+15.5)
Table 2-13 Basic Tones
Basic Tone No. Frequency (Hz) Level (dB)
01 420 - 13
02 520 - 13
03 580 - 13
04 660 - 13
05 700 - 13
06 800 - 13
07 880 - 13
08 1050 - 13
09 430 - 13
10 440/480 -13/-13
11 480/620 -13/-13
12 440 -16
13 -- Reserve -- -
14 520 / 650 -19 / -13
15 650 / 780 -19 / -13
16 780 / 1040 -19 / -13
17 520 / 650 -13 / -19
ISSUE 1.0 SL1000/SL1100
Program
80
Programming Manual 2-419