Item No. Item Description Input Data Default
13 T314 Specifies the timer value in 1/100ths of a
second of the timer to be started when
message segment is received.
1 ~ 254 seconds 4 seconds
14 T316 Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is sent.
(T317 + 1) ~ 254 sec-
onds
120 seconds
15 T317 Specifies the timer value in 1/100ths of a
second of the timer to be started when RE-
START is received.
1 ~ (T316-1) 60 seconds
16 T318 Specifies the timer value in 1/100ths of a
second of the timer to be started when
RES is sent. This timer is valid for user
side use only.
1 ~ 254 seconds 4 seconds
17 T319 Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND is sent. This timer is valid for
user side use only.
1 ~ 254 seconds 4 seconds
18 T320 Specifies the timer value in 1/100ths of a
second when B-channel access: connec-
tion is received or D-channel access: DL-
ESTABLISH confirmation or indication is
received.
1 ~ 254 seconds 30 seconds
19 T321 Specifies the timer value in 1/100ths of a
second of the timer to be started when
STATUS ENQ is received.
1 ~ 254 seconds 30 seconds
20 T322 Specifies the timer value in 1/100ths of a
second upon D-channel failure.
1 ~ 254 seconds 4 seconds