Item No.
Item Table Input Data Default
08 PBX Access Code
Use this option to enter the PBX Access
Code.
When the system is behind a PBX, this is
the code users dial to access a PBX trunk.
Toll Restriction begins after the PBX ac-
cess code.
For PBX trunks (Program 14-04) the sys-
tem only Toll Restricts calls that contain the
access code.
Always program this option when the sys-
tem is behind a PBX, even if you don’t want
to use Toll Restriction.
PBX Access Codes can have up to two dig-
its, using 0-9, #,
*
and LINE KEY 1 (don’t
care).
When using Account Codes, do not use an
asterisk in a PBX access code. Otherwise,
after the
*
, the trunk stops sending digits
to the central office.
Entries 1~4 correspond to the 4 PBX Ac-
cess Codes.
Each code can have up to two digits.
1 ~ 4 Dial
(Up to two digits)
Tables1~4=Nosetting
09 Specific Dial Outgoing Code 1~20 Dial
(Up to eight digits)
Tables1~20=Noset-
ting
10 Outgoing Call Code Setup 1~20 Dial
(Up to four digits)
Tables1~20=Noset-
ting