Item No. Item Input Data Default Related Program
20 Long Conversation Disconnect
(Trunk to Trunk)
This time determines how long the
system waits before disconnecting a
DISA caller or any trunk-to-trunk
(such as Tandem Trunking) conversa-
tion call after the Long Conversation
tone is heard.
0 ~ 64800 seconds 15 seconds 25-07-08
21 DISA Internal Paging Time
This is the maximum length of an In-
ternal Page placed by a DISA caller. If
the Page continues longer than this
time, the system terminates the DISA
call.
0 ~ 64800 seconds 30 seconds 25-07-09
22 DISA External Paging Time
This is the maximum length of an Ex-
ternal Page placed by a DISA caller. If
the Page continues longer than this
time, the system terminates the DISA
call.
0 ~ 64800 seconds 30 seconds 25-07-10
23 Page Announcement Duration
This timer sets the maximum length
of Page announcements. (Affects Ex-
ternal Paging only)
0 ~ 64800 seconds 1200 seconds 31-01-02
24 Mobile Extension answer time 1 ~ 64800 seconds 3 seconds 22-01-12
25 Mobile Extension callback time 1 ~ 64800 seconds 15 seconds 20-01-16
Conditions
These timers are used when an extension or trunk is assigned to a class from 1 to 16 in 20-29-01
or 20-30-01. When the timer class is set to 0, the system-wide timer is used.
All defaults are the same as the system-wide timers.