Item No. Item Input Data Default Related Program
10 Dial Digits for Toll Restriction
Path
If this option is programmed with
an entry other than 0, a call does
not have a talk path unless the
user dials at least the number of
digits entered in this option when
placing an outgoing call.
This means that an entry of 4 or
higher in this program causes a
problem when dialing 911 (USA
only). Since it is only a 3-digit num-
ber, the call does not have a talk
path, preventing the emergency
dispatcher from hearing the caller.
This option should be kept at its
default setting of 0 to prevent any
problems with dialing 911 (USA
only).
0~36 0
11 Inter-Digit Time for Toll Restric-
tion Path Control
0 ~ 60 seconds 10
12 Dial E911 Routing Without Trunk
Access
If enabled (1), an extension user
can dial 911 (USA only) without
first dialing a trunk access code or
pressing a line key. If disabled (0),
an extension user must dial a trunk
access code (e.g., 9) or press a
line key before dialing 911 (USA
only).
0 = Trunk Access Code
Required
1 = Trunk Access Code
Not Required
1
13 Alarm Ring Timer (E911)
Use this option to set the duration
of the E911 Alarm Ring Time. If set
for 0, the E911 Alarm does not
ring.
0, 1~ 64800 seconds
(0=Off)
0 11-12-56
20-08-16
14 Forced Account Code Inter-digit
Timer
The system waits this time for a
user to enter a Forced Account
code.
0 ~ 64800 seconds 3 seconds
15 Outgoing Disable on Incoming
Line (Toll Restriction)
Enable or disable the Outgoing
Disable on Incoming Line feature.
0=Disable(Off)
1 = Enable (On)
0 15-01-05
21-01-16
21-01-17
80-03-01
16 Supervise Dial Detection Timer
With the Outgoing Disable on In-
coming Line feature, if dial tone is
not detected after the extension
answers an incoming line, the sys-
tem determines the call is unable
to complete and releases the
DTMF receiver.
0 ~ 64800 seconds 20 seconds 15-01-05
21-01-16
21-01-17
80-03-01
17 Restriction Digit in Outgoing
Disable on Incoming Line
With the Outgoing Disable on In-
coming Line feature, determine the
number of digits to be dialed be-
fore the call should be discon-
nected.
Digits1~9 4 15-01-05
21-01-15
21-01-16
80-03-01
18 Reset Dial After Failure of Trunk
Access
Enable (1) or Disable (0) the ability
to continue to dial codes or exten-
sions after receiving Trunk Busy.
This needs to be set to Enabled (1)
for the Forced Trunk Disconnect
feature to work.
0=Disable(Off)
1 = Enable (On)
0
ISSUE 1.0SL1000/SL1100
Program
21
Program 21 : Outgoing Call Setup2-218