EasyManua.ls Logo

NEC SL1000 - Page 473

NEC SL1000
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Name Input Data Default
39 Receive Line Block recover min Time 1 ~ 255 (64 ms ~ 16320 ms) 32 (2048 ms)
40 Transmit Remove Ring Time 0 ~ 255 (0 ms ~ 1020 ms) 0 (0 ms)
41 Transmit Clear Signal Send Time 1 ~ 255 (16 ms ~ 4080 ms) 63 (1008 ms)
42 Transmit Seizure Signal Time 1 ~ 255 (8 ms ~ 2040 ms) 100 (800 ms)
43 Group A Response Time 1~32(1sec~32sec) 12(12sec)
44 Group A Tone Complete Time 1~32(1sec~32sec) 12(12sec)
45 Group B Response Time 1~32(1sec~32sec) 12(12sec)
46 Group B Tone Complete Time 1~32(1sec~32sec) 12(12sec)
47 Group C Response Time 1~32(1sec~32sec) 12(12sec)
48 Group C Tone Complete Time 1~32(1sec~32sec) 12(12sec)
49 Group I Signal Time 1~32(1sec~32sec) 12(12sec)
50 Group I Tone Complete Time 1~32(1sec~32sec) 12(12sec)
51 Group II Signal Time 1~32(1sec~32sec) 12(12sec)
Conditions
After set from Program 81-13-01 to 42, the E1 unit will be reset.
Feature Cross Reference
None
ISSUE 1.0 SL1000/SL1100
Program
81
Programming Manual 2-451

Table of Contents

Other manuals for NEC SL1000

Related product manuals