Item No. Item Input Data Default
14 TDM Tx Gain Compression mode 0=Disable
1 = Enable
1
15 TDM Tx Gain Compression
Threshold
0=-42dBm
1=-41dBm
:
42 = 0 dBm
41
16 - Not Used -
17 - Not Used -
18 - Not Used -
19 RTP Echo Canceller mode 0=Disable
1 = Enable
0
20 RTP Echo Canceller NLP mode 0=Disable
1 = Enable
0
21 - Not Used -
22 RTP Echo Canceller NLP Thresh-
old
0~15 12
23 - Not Used -
24 - Not Used -
25 - Not Used -
26 RTP Echo Canceller Echo Type 0=Disable
1 = Line Echo Canceller
2 = Acoustic Echo Canceller
0
27 - Not Used -
28 RTP Tx Level Control 0=Disable
1 = TxLevelControl mode
2 = TxAutomaticLevelControl mode
3 = HLC
Type1,Type8=3
Type 9, 11~15 = 0
29 RTP Tx Level Control Level 0~16(-24~24dB)
0=-24dB
1=-21dB
2=-18dB
:
8=0dB
:
14=18dB
15=21dB
16=24dB
8
30 - Not Used -
31 RTP Tx HLC Threshold 0 ~ 42 (- 42 dBm ~ 0 dBm)
0=-42dBm
1=-41dBm
:
42 = 0 dBm
Type1,Type8=36
Type 9, 11~15 = 42
32 RTP Tx Gain Compression mode 0=Disable
1 = Enable
Type1,Type8=1
Type 9, 11~15 = 0
33 RTP Tx Gain Compression
Threshold
0 ~ 42 (- 42 dBm ~ 0 dBm)
0=-42dBm
1=-41dBm
:
42 = 0 dBm
Type1,Type8=36
Type 9, 11~15 = 42
34 - Not Used -
35 - Not Used -
36 - Not Used -
ISSUE 1.0 SL1000/SL1100
Program
84
Programming Manual 2-499