Program 20 : System Option Setup
20-18 : Service Tone T
imers
Level:
IN
Description
Use Program 20-18 : Service Tone T
imers to set the values for the system service tone timers.
Refer to the following chart for a description of each option, its range and default setting.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 Extension Dial
Tone T
ime
0 ~ 64800 seconds After getting Intercom dial tone, a
telephone user has this time to dial
the first digit of the Intercom call.
30
02 Busy Tone Timer 0 ~ 64800 seconds 15
03 Congestion Tone 0 ~ 64800 seconds A Busy Tone when system resour-
ces run short. (Such as DTMF re-
ceiver resources).
10
04 Call Waiting Tone
Timer
0 ~ 64800 seconds This option sets the time between
Call Waiting tones. This timer also
sets the time between Off-Hook Sig-
naling alerts.
10
05 Multiline Confir-
mation Tone
0 ~ 64800 seconds 10
06 Interval of Call
Waiting Tone
3 ~ 64800 seconds 10
07 Intrusion Tone
Repeat Time
0 ~ 64800 seconds After a call is interrupted (such as
Barge-In, Voice Mail Conversation
Recording, or Voice Over), the sys-
tem repeats the Intrusion Tone after
this time. Normally, you should enter
0 to disable this time.
0
08 Conference Tone
Interval
0 ~ 64800 seconds 0
09 Warning Beep
Tone Signaling
Interval
0 ~ 64800 seconds 60 14-01-18