Program 80 : Basic Hardware Setup for System
80-10 : MF Tone Receiver Setup
Level:
MF
Description
Use Program 80-10 : MF Tone Receiver Setup
to define the various level and time for MF Tone
Receiver.
Input Data
MF Tone Receiver Type Number 1 = MF Receiver for Extension
2 = MF Receiver for Trunk
3 = -- Reserve --
4 = -- Reserve --
5 = -- Reserve --
Item
No.
Item Input Data Default
01 Detection Level 0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
Refer below
02 Start delay time 0 ~ 255 (0.25 step, 0 ms ~ 64 ms) Refer below
03 Min. detect level 0 ~ 15
detect level 0 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 1 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 2 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 3 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 4 = - 30 dBm (0) ~ - 45 dBm (15)
detect level 5 = - 35 dBm (0) ~ - 50 dBm (15)
detect level 6 = - 40 dBm (0) ~ - 55 dBm (15)
Refer below
04 Max. detect level 0 ~ 15
detect level 0 = 0 dBm (0) ~ - 15 dBm (15)
detect level 1 = - 5 dBm (0) ~ - 20 dBm (15)
detect level 2 = - 10 dBm (0) ~ - 25 dBm (15)
detect level 3 = - 15 dBm (0) ~ - 30 dBm (15)
detect level 4 = - 20 dBm (0) ~ - 35 dBm (15)
detect level 5 = - 25 dBm (0) ~ - 40 dBm (15)
detect level 6 = - 30 dBm (0) ~ - 45 dBm (15)
Refer below
05 twist level 0 ~ 9 (1 dB ~ 10 dB) Refer below
06 S/N ratio 0 ~ 4 (- 5 step, 0 dB ~ - 20 dB) Refer below
07 ON detect time 1 ~ 255 (15 + 15 ms ~ 3825 ms) Refer below
08 OFF detect time 1 ~ 255 (15 + 15 ms ~ 3825 ms) Refer below