Program 81 : Basic Hardware Setup for Trunk
81-20 : ISDN PRI
Function Setup
Level:
MF
Description
This program defines the various basic data for the function of ISDN PRI.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 Layer3 information
element check
0 = normal
1 = special
0 81-18-01
02 Setup information
element check
0 = normal
1 = special
0 81-18-01
03 The sending of in-
formation mes-
sage
0 = disable
1 = enable
0 81-18-01
04 Restart detection
operation
0 = normal
1 = special
0 81-18-01
05 Setup detection
operation
0 = normal
1 = special
0 81-18-01
06 Notify detection
operation
0 = normal
1 = special
0 81-18-01
07 Setupack detec-
tion operation
0 = normal
1 = special
0 81-18-01
08 Layer3 message
detection opera-
tion
0 = normal
1 = special
special:
The Layer3 message detection op-
eration in abnormal state.
0 81-18-01
09 T301 timeout ex-
tension
0 = disable
1 = enable
enable:
10 times value of T301 is set.
0 81-18-01
81-06-01
10 T304 timeout ex-
tension
0 = disable
1 = enable
enable:
10 times value of T304 is set.
0 81-18-01
81-06-04
11 T303 timeout op-
eration
0 = normal
1 = special
special:
In case of the T303 timeout, the re-
lease message is sent to system.
0 81-18-01
12 T305 timeout op-
eration
0 = normal
1 = special
special:
In case of the T305 timeout, the re-
lease message with CAUSE102 is
sent to outside.
0 81-18-01
13 T203 enable (T-
point)
0 = disable
1 = enable
0 81-18-01
14 PRI Layer2 error
detection opera-
tion
0 = normal
1 = special
0 81-18-01
15 PRI outstanding
pluse one opera-
tion
0 = normal
1 = special
0 81-18-01
16 BRI CRC error de-
tection operation
0 = normal
1 = special
0 81-18-01
ISSUE 2.0 SL2100
Programming Manual 2-515
Program
81