Program 20 : System Option Setup
20-45 : Remote Watch Setup
Level:
IN
Description
Use Program 20-45 : Remote Watch Setup
to defines the remote watch.
Input Data
Terminal Number 1 ~ 6
Item
No.
Item Input Data Description Default
01 Ring Terminal for Re-
mote Inspection
Extension Number (Up
to 8 digits)
Extension number for Remote Inspection No Setting
02 Ring Time Setting 0000 ~ 2359 Ringing start time for Inspected Extension 0000
03 Ring Timer 0 ~ 60 Ringing continue time for inspected exten-
sion
0
04 Auto Dial Number
Area Setting
0 ~ 999 Speed dial number when detect no answer
at extension and make emergency call
0
05 VRS Message for An-
swer
0 ~ 100 VRS message number when inspected ex-
tension answered
0
06 VRS Message for Au-
to Dial
0 ~ 100 VRS message number when emergency
call destination answered.
0
07 Time of Repeat Auto
Dial
0 ~ 255 Repeat number for making emergency
call.
0
08 Auto Dial Calling
Time
0, 10 ~ 3600 Calling continue time when making emer-
gency call.
0
09 Interval of Auto Dial 0, 10 ~ 3600 0