Program 82 : Basic Hardware Setup for
Extension
82-07 : CODEC Filter Setup for Analog Station Port
Level:
IN
Description
Use Program 82-07 : CODEC Filter Setup for Analog Station Port to set the filter value of the
CODEC (QSLAC) filter of each analog port.
Input Data
Station Port Number 1 ~ 128
Item
No.
Item Input Data Default
01 CODEC Filter Type 0 = No filter
1 = Type 1: Line loss 0dB
2 = T
ype 2: Line loss 4dB
3 = Type 3: Line loss 8dB
4 = Type 4: Not Used
5 = Type 5: Not Used
6 = Type 6: Not Used
7 = Type 7: Not Used
8 = Type 8: 600 ohms North America
9 = Type 9: Not Used
10 = Type 10: Not Used
11 = Type 11: Not Used
12 = Type 12: Not Used
13 = Type 13: Not Used
14 = Type 14: 600 ohms 0dBr
15 = Type 15: Not Used
2 (: Type 2: Line loss
4dB)
Conditions
When the Side Tone level was so laud or small on the default, check the Side Tone by a customer
site using the following data and establish something best for the side tone.
Do not change the data from the default when the side tone is no problem.