Program 90 : Maintenance Program
90-10 : System Alarm Setup
Level:
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. Y
ou can designate
an alarm as Major or Minor. This program also assigns whether or not the alarm information is
reported to the predefined destination.
Input Data
Alarm Number 1 ~ 200
Item
No.
Item Input Data Default
01 Alarm Type 0 = Not Set
1 = Major Alarm
2 = Minor Alarm
*1
02 Report 0 = Not Report (No autodial)
1 = Report (autodial)
*1
Table 2-22 Description of Alarm
Alarm
No.
Name
Item
No.01
de-
fault
Item
No.02
de-
fault
Content of
alarm
< generation
timing >
Cause Measures Recovery
Alarm
Status
1 PKG Initial-
ize Error
2 0 It failed in the
initialization of
the package.
The package
was not able to
be started nor-
mally.
<The package
starts >
1.
The unit
doesn't insert
firmly.
2. The unit is tak-
en out once,
and it doesn't
insert it again
firmly.
3. Because infor-
mation on the
unit that had
been mounted
before re-
mains, a unit
different from
the information
doesn't do the
initialization
completion.
1. Please insert
the unit firmly.
2. Please insert
the unit firmly.
3. Please delete
slot informa-
tion with
PRG90-05 and
insert the unit
again.
It doesn't re-
cover it au-
tomatically.
When the
unit is rec-
ognized
again, the
error is re-
covered.
ERR
REC
ISSUE 2.0 SL2100
Programming Manual 2-581