Program 34 : Tie Line Setup
34-07 : E&M Tie Line T
imer
Level:
IN
Description
Use Program 34-07 : E&M Tie Line T
imer to define the system service tone timers.
Input Data
Item
No.
Item Input Data Default
01 First Digit Pause (E&M Immediate
Start)
0 ~ 64800 seconds 3 seconds
02 First Digit Pause (E&M Wink Start) 0 ~ 64800 seconds 0
03 First Digit Pause (LD Trunk) 0 ~ 64800 seconds 3 seconds
04 LD Trunk Guard Time 0 ~ 64800 seconds 0
05 Trunk Answer Detect Timer for
E&M
0 ~ 64800 seconds 30 seconds
Conditions
If Program 34-07-05 is left at default (30) the transferred call recalls to the station that performed the
transfer when not answered.