Item
No.
Item Input Data Description Default
04 Max. Detect Level 0 ~ 15
DTMF Tone 0 = 0 dBm
(0) to - 15 dBm (15)
DTMF T
one 1 = - 5 dBm
(0) to - 20 dBm (15)
DTMF Tone 2 = - 10
dBm (0) to - 25 dBm (15)
DTMF Tone 3 = - 15
dBm (0) to - 30 dBm (15)
DTMF Tone 4 = - 20
dBm (0) to - 35 dBm (15)
DTMF Tone 5 = - 25
dBm (0) to - 40 dBm (15)
DTMF Tone 6 = - 30
dBm (0) to - 45 dBm (15)
Refer below
05 Forward Twist Level 0 ~ 9 (1 dB ~ 10 dB) Refer below
06 Backward Twist Level 0 ~ 9 (1 dB ~ 10 dB) Refer below
07 ON Detect Time 1 ~ 255 (15 + 15 ms ~
3825 ms)
Refer below
08 OFF Detect Time 1 ~ 255 (15 + 15 ms ~
3825 ms)
Refer below
10 Sensitivity Level 0 ~ 1 sensitivity level 0: normal
sensitivity level 1: improve Mis-detection
for talking
Refer below
Default
Item
No
Item Type 1 Type 2 Type 3 Type 4 Type 5
01 Detect Level 0 0 0 0 0
02 Start delay time 0 0 0 0 0
03 Min. detect level 10 (- 20 dBm) 15 (- 25 dBm) 15 (- 25 dBm) 10 (- 20 dBm) 10 (- 20 dBm)
04 Max. detect level 2 (- 2 dBm) 2 (- 2 dBm) 2 (- 2 dBm) 2 (- 2 dBm) 2 (- 2 dBm)
05 Forward twist level 5 (6 dBm) 5 (6 dBm) 5 (6 dBm) 5 (6 dBm) 5 (6 dBm)
06 Backward twist level 0 (1 dBm) 0 (1 dBm) 0 (1 dBm) 0 (1 dBm) 0 (1 dBm)
07 ON detect time 3 (60 ms) 2 (60 ms) 3 (60 ms) 3 (60 ms) 3 (60 ms)
08 OFF detect time 2 (45 ms) 1 (30 ms) 2 (45 ms) 2 (45 ms) 2 (45 ms)
10 Sensitivity Level 0 0 0 0 0
Conditions
None
Feature Cross Reference
None
ISSUE 2.0 SL2100
Programming Manual 2-491
Program
80