EasyManua.ls Logo

NEC SL2100 - Page 517

NEC SL2100
678 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item
No.
Item Input Data Default
08 OFF Minimum Time 0 ~ 255 (30 + 30 ~ 7680 ms) Refer below
09 OFF Maximum Time 0 ~ 255 (30 + 30 ~ 7680 ms) Refer below
12 Frequency No. 1 1 ~ 8
(Frequency Table No. set by 80-07)
Refer below
13 Frequency No. 2 0 ~ 8 (0 = Not Used)
(Frequency Table No. set by 80-07)
Refer below
Default
Item Name Type 1 (DT) Type 2 (BT) Type 3 (RBT) Type 4 Type 5
1 Detect Level 0 0 0 0 0
2 Min. detect level 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25 dBm) 15 (- 25
dBm)
1
3 S/N ratio 4 (- 20 dB) 4 (- 20 dB) 4 (- 20 dB) 1 0
4 No tone time 132 (3990 ms) 132 (3990 ms) 132 (3990 ms) 132 (3990
ms)
0
5 Pulse Count 1 1 1 2 2
6 ON min. time 45 (1380 ms) 12 (390 ms) 23 (720 ms) 3 (120 ms) 5
7 ON max. time 0 20 (630 ms) 74 (2250 ms) 13 (420 ms) 15
8 OFF min. time 1 (60 ms) 12 (390 ms) 59 (1800 ms) 3 (120 ms) 2
9 OFF max. time 1 (60 ms) 20 (630 ms) 232 (6990 ms) 13 (420 ms) 5
12 Frequency No 1 1 3 2 3 1
13 Frequency No 2 2 4 3 4 2
14 Twist Level 0 0 0 0 0
Conditions
None
Feature Cross Reference
None
ISSUE 2.0 SL2100
Programming Manual 2-493
Program
80

Table of Contents