-214-
Drive error code (2/6)
Code(
H
)
Description
Panel
Indicator
Action
0m10h
Command cannot execute in the recovery of
communication error
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m10
0m11h
A timeout error occurred while waiting for
response from drive #n.Or The power supply is
not supplied to the drive.
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m11
0m12h
Detected time-out of the data transfer ready
reaponse with Drive-n.
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m12
0m13h
ACK from drive n was not detected.)
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m13
0m14h
Drive #n failed to communicate because of being
pulled out.Or drive isn’t installed.
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m14
0m15h
The command to Drive n became a parameter
error.
(FRU)
F/W, Drive F/W
CHK
0m15
0m16h
Detected time-out of the data response with
Drive –n.
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m16
0m17h
Command cannot execute in initialization of
Drive-n.
(FRU)
Drive n I/F cable, Drive n, CONTROLLER
BOARD
CHK
0m17
0m18h
The command to Drive n terminated abnormally
by Sense Key and ASC/ASCQ code outside
assumption.
(FRU)
F/W, Drive F/W
CHK
0m18
0m19h
The command transmission from Drive n to
Encryption Key Manager is retry-over.
(FRU)
LAN cable, Drive n I/F cable, CONTROLLER
BOARD
CHK
0m19
0m1Ah
The command transmission from Encryption
Key Manager to Drive n is retry-over.Encryption
Key
(FRU)
LAN cable, Drive n I/F cable, CONTROLLER
BOARD
CHK
0m1A
0m1Bh
The cleaning medium loaderd to Drive n reached
the endurance frequency (50 times).
(FRU)
Cleaning Cartridge
CHK
0m1B
0m1Ch
Detected the media error with Drive n.
(FRU)
Cartridge
CHK
0m1C
0m1Dh
Detected the hardware error with Drive n.
(FRU)
CHK
0m1D

Table of Contents