Dead-time counter
When the a channel’s DTE bit is set in MCCON, the dead-time counter delays the 
passive-to-active transitions of both MCO outputs. The dead-time counter starts counting 
down, from the channel’s DT value (in the MCDT register) to 0, whenever the channel’s A 
or B output changes from active to passive. The transition of the other output from passive 
to active is delayed until the dead-time counter reaches 0. During the dead time, the 
MCOA and MCOB output levels are both passive. Figure 124
 shows operation in edge 
aligned mode with dead time, and Figure 125
 shows center-aligned operation with dead 
time.
 
Fig 123. Center-aligned PWM waveform without dead time, POLA = 0
Fig 124. Edge-aligned PWM waveform with dead time, POLA = 0
MAT MAT LIMLIM
0
0
POLA = 0
MCOA
MCOB
active
active
passive
passive
passive passiveactive
active
MAT MATLIM LIM
0
POLA = 0
timer reset timer reset
MCOA
MCOB
active active
passive
passive
passive
passive
active
active
DT
DT DT
DT