Technical Reference Guide – Command descriptions > 112
> Range:
Range n = 0 – 7, Number of tab channel
> Out of range:
If n > 7, the VFU value will be ignored.
> Additional details:
Within each channel there can be up to 16 vertical tabs
which are independently set.
In order to access the vertical tabs within each channel VT
or CHR$(11) can be used.
Tabs set by the ESC B command correspond to channel no.
0.
F
ORM
LENGTH
SET
BY
INCHES
> Code: ESC C NUL n
> Compatibility:
ML1190 eco: EPSON LQ/IBM
ML1120 eco: EPS FX/IBM III
> Function:
Upon receipt of this command the printer sets the form
length to n in.
> Range:
n = 1 – 22 (Epson), Number of inches
n = 1 – 255 (IBM)
> Out of range:
n = 0 (or n > 22 in Epson mode) this command will be
ignored.
> Additional details:
The skip perforation will be cleared when the n is valid
data.
Top of form position is set by this command.
> Related functions: