Technical Reference Guide – Command descriptions > 87
Upon power up the default tabs are set at columns 9, 17,
25, 33... and every eight spaces after that, according to
the default character pitch.
The spaces generated by a horizontal tab will not be
scored.
> Related Functions:
Horizontal tab stop set – ESC D
R
ESET
TAB
SETTINGS
TO
POWER
-
ON
DEFAULT
VALUES
> Code: ESC R
> Compatibility:
ML1190 eco: IBM
ML1120 eco: IBM III
> Function:
This command sets horizontal tabs at every eighth
character starting at column 9 and clears all vertical tabs.
> Additional details:
The horizontal tabs will be set according to the default
character pitch.
E
XECUTE
ABSOLUTE
HORIZONTAL
DOT
POSITION
> Code: ESC $ n1 n2
> Compatibility:
ML1190 eco: EPSON LQ
ML1120 eco: EPS FX
> Function:
Moves the printhead to the specified absolute horizontal
dot position in a line from the left margin; subsequent data
is printed from this position.
> Range:
In dot position setting, n1 becomes low byte and n2
becomes high byte.