Technical Reference Guide – Specifications > 181
> Dielectric strength
3000 VAC (50/60 Hz)
(No damage will result when the above voltage is applied 
between the AC input line and frame for 1 minute.)
E
NVIRONMENTAL
 
CONDITIONS
> Ambient temperature and relative humidity
The printer must be packaged during storage.
Avoid condensation at all times.
> Vibration
Operating: 0.3G (5 – 150 Hz) or less (except at resonant 
frequency).
Non-operating: 1G (5 – 150 Hz) or less (except at resonant 
frequency).
Packing: 1.05G (5 -150 Hz) or less (except at resonant 
frequency). 
> Impact (Drop)
Packing: 0.914 m (36 in) (one corner, three edges and six 
sides)
N
OISE
> Measurement method
The printer is placed 2.46 ft (0.75 m) above the floor and 
the microphone is set 3.28 ft (1 m) and 4.92 ft (1.5 m) 
above the floor (in compliance with ISO 7779).
> Printing operation
CONDITION TEMPERATURE REL. HUMIDITY
Operating 41 – 95°F
(5 – 35 °C)
20 – 80% RH
Storage 14 – 122 °F
(-10 – 50 °C)
5 – 95% RH