2KZ/2K0
1-4-6
4901 Bridge conveying sensor 1
non arrival jam
The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 1.
B
4902 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 2.
B
4903 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from cassette 3.
B
4908 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from duplex section.
B
4909 The bridge conveying sensor 1 (BRCS1) does not
turn on during paper feed from the MP tray.
B
4911 Bridge conveying sensor 1
stay jam
The bridge conveying sensor 1 (BRCS1) does not
turn off during paper feed from cassette 1.
I
4912 The bridge conveying sensor 1 (BRCS1) does not
turn off during paper feed from cassette 2.
I
4913 The bridge conveying sensor 1 (BRCS1) does not
turn off during paper feed from cassette 3.
I
4918 The bridge conveying sensor 1 (BRCS1) does not
turn off during paper feed from duplex section.
I
4919 The bridge conveying sensor 1 (BRCS1) does not
turn off during paper feed from the MP tray.
I
5001 Bridge conveying sensor 3
non arrival jam
The bridge conveying sensor 3 (BRCS3) does not
turn on during paper feed from cassette 1.
I
5002 The bridge conveying sensor 3 (BRCS3) does not
turn on during paper feed from cassette 2.
I
5003 The bridge conveying sensor 3 (BRCS3) does not
turn on during paper feed from cassette 3.
I
5008 The bridge conveying sensor 3 (BRCS3) does not
turn on during paper feed from the duplex section.
I
5009 The bridge conveying sensor 3 (BRCS3) does not
turn on during paper feed from theMP tray.
I
5011 Bridge conveying sensor 3
stay jam
The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from cassette 1.
I
5012 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from cassette 2.
I
5013 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from cassette 3.
I
5018 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from duplex section.
I
5019 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from the MP tray.
I
Code Contents Conditions
Jam
location*
*: Refer to figure 1-4-1 for paper jam location (see page 1-4-1).