6-8
AMR Charging Contact Inspection
The AMR charging contacts wear during normal operation and should be inspected every 3 months to
determine if they need to be replaced. Measure the overall height of each charging contact. If the
height is less than 7.0 mm, the charging contacts must be replaced.
7.0 min.
6 Maintenance
6-11
AMR (Autonomous Mobile Robot) MD-series Platform User's Manual (I681)
6-8 AMR Charging Contact Inspection