Parts and FunctionsFP2/FP2SH
2 − 59
2.11 I/O Mixed Units Specifications
Notes
• Keep the number of input and output points per common
which are simultaneously on within the following range as de-
termined by the input voltage and ambient temperature.
Number of
points per com-
mon which are
simultaneous
on
Ambient temperature (°C/°F)
47/
116.6
55/
131
Input Output
32
22
18
0
38/
100.4
32
22
18
26.4V DC
24V DC
• The load current will vary depending on the power supply for
driving the internal circuit. Adjust the load current referring to
the following range.
Max. load current (mA)
Power supply for driving
internal circuit (V)