Chapter 2: Troubleshooting Your Library
Working With Command History Logs
Quantum Scalar i6000 User’s Guide 115
Working With Command History Logs
The Command History Log dialog box enables you to view command
and response activity that has occurred with externally addressable
library devices, including the LMC, controller LUNs, partitions, and
drives. This information can help you isolate the source of an issue, such
as a library device or host application.
AMBER, solid Tower is varied off, online or offline. Vary off
status trumps online/offline status display.
Note: It does not matter if the tower is
offline or offline if it is varied off or
being varied off.
BLINKING GREEN
(3 sec ON, 1 sec OFF
Tower is varied on and UI takes the tower
offline
BLINKING AMBER
(10 HZ frequency)
Tower door is opened while tower is still
varied on, or is currently in performing a
vary-on or vary-off operation before
completing the state transition, regardless
of being logically online or offline, hereby
interrupting tower motor control.
BLINKING (3 secs
AMBER, 1 sec GREEN)
Aisle door opened while tower is varied on,
regardless of being logically online or
offline, hereby interrupting tower motor
control.
Note: If the tower was varied off before
the aisle power was interrupted, the
tower continues to display the vary
off blink pattern.
10 Hz blinking pattern Tower identification initiated
Lighting Pattern Description