Chapter 10: Path Failover
Configuring Data Path Failover
Quantum Scalar i6000 User’s Guide 381
Advanced Data Path
Failover (ADPF)
Requirements
To configure a tape drive for advanced data path failover, you need the
following:
The library must have a Storage Networking license installed.
The tape drive to be configured for data path failover must be
licensed for storage networking (see
License Drives for Path Failover
on page 359.
The tape drive must be an LTO-6 or later Fibre Channel tape drive.
The tape drive must be connected to an Ethernet Expansion Blade
(EEB) via an Ethernet cable.
Neither FC port on the drive may be connected to a FC I/O blade.
The tape drive topology settings must be set to Point to Point (see
Configuring Fibre Channel Drive Speed, Topology, and Loop ID on
page 202).
APFO driver must be installed on the host(s).
Enabling/Disabling ADPF
To enable or disable advanced data path failover functionality:
1 From the main console, select Setup > Drives > Access > Data
Path Failover. Or, via the SNW Wizard: Select Setup > SNW
Wizard.
2 Click Next.
3 From the options screen, select Data Path Failover and click Next.
The Data Path Failover (DPF) dialog box appears. Drives with ADPF
configured have check marks in the ADPF column.