Chapter 15: Maintaining Your Library
Maintenance Actions
576 Quantum Scalar i6000 User’s Guide
• Save a trace file - Users can access completed trace files and
download them to workstations for analysis.
• Set configuration options - Users can select an interface used to
capture traffic as well as set the size - in MBs - of the completed
trace file. Interface options include:
•External
•Internal
• Loopback
•All
• Start, stop and delete a trace
Start a Network Trace Manually
1 From the menu bar, click Tools > Capture Network Trace. The
Capture Network Trace screen appears.
2 From the Configuration Options area, select the type of network
trace you want to perform:
• External — configures the trace tool to capture all traffic
between the library and the outside world. As most networks
are now switched, this should not cause any traffic to be
captured from other workstations on the same segment, except
for some broadcast packets.
• Internal — configures the trace tool to capture all traffic
internal on the library backbone. This has to be traffic
originating, or passing through the MCB. Traffic between the
RCU and the PRPs for example will NOT be captured.
• Loopback — a virtual interface on the MCB. This will ONLY
capture traffic which uses this specific interface for daemons
and other processes internally to the MCB.
• All — captures all traffic on all interfaces combined.
3 Enter a value in the Max File Size (MB) field from 0 to 1000MB. The
trace will automatically stop when the value in the Max File Size
field is reached.

Table of Contents

Other manuals for Quantum Scalar i6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i6000 and is the answer not in the manual?

Quantum Scalar i6000 Specifications

General IconGeneral
Form FactorRack-mountable
InterfaceFibre Channel, SAS
Product TypeTape Library
CoolingRedundant cooling fans
DimensionsVaries by configuration
WeightVaries by configuration
Operating Humidity20% to 80% non-condensing
ScalabilityScalable
Drive TypesLTO
RedundancyRedundant power supplies
ManagementWeb-based management
Tape TechnologyLTO
Supported MediaLTO Ultrium 9, LTO Ultrium 8, LTO Ultrium 7, LTO Ultrium 6
Power SupplyRedundant power supplies
Non-operating Humidity5% to 95% non-condensing

Related product manuals