Chapter 15: Maintaining Your Library
Maintenance Actions
Quantum Scalar i6000 User’s Guide 627
Drive Sled Assembly Test
The drive sled assembly test performs the following tasks:
• Calibrates the drive sled
• Checks the quality of the sled’s fiducial
• Performs Get/Put to the drive
Scan Barcode Test
The scan barcode test performs the following tasks:
• Moves to selected cell coordinate and scans the barcode label
• Checks to ensure the label reads the same from top to bottom
• Verifies the quality of the barcode labels and checks to make sure
barcode labels are in a readable position
I/E Station Assembly Test
The I/E station assembly test performs the following tasks:
• Locks and unlocks the I/E station
• Calibrates the I/E station and check offsets collected
• Checks each magazine’s fiducial in the I/E station
• Performs Get/Put tests on all the I/E station cells
Scanner Fiducial Test
The scanner fiducial test performs the following tasks:
• Scans and checks each magazine fiducial
• Scans and checks each drive sled fiducial
• Tests the calibration sensor
• Calibrates and checks repeatability, up to three times for failed
calibration targets
Understanding the Verification Test Inventory
The verification tests generate inventory lists that provide specific
information about the library's configurations. Inventory lists for the
library, drives, and blades are available. On the Verification Test dialog

Table of Contents

Other manuals for Quantum Scalar i6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i6000 and is the answer not in the manual?

Quantum Scalar i6000 Specifications

General IconGeneral
Form FactorRack-mountable
InterfaceFibre Channel, SAS
Product TypeTape Library
CoolingRedundant cooling fans
DimensionsVaries by configuration
WeightVaries by configuration
Operating Humidity20% to 80% non-condensing
ScalabilityScalable
Drive TypesLTO
RedundancyRedundant power supplies
ManagementWeb-based management
Tape TechnologyLTO
Supported MediaLTO Ultrium 9, LTO Ultrium 8, LTO Ultrium 7, LTO Ultrium 6
Power SupplyRedundant power supplies
Non-operating Humidity5% to 95% non-condensing