Chapter 15: Maintaining Your Library
Maintenance Actions
632 Quantum Scalar i6000 User’s Guide
Joint Alignments
The Joint Alignments graphical report shows the results for tests of
alignment between frames. It also shows the results for tests of accessor
travel to all corners of the library.
• If the graphical report shows one or more failed results for joint
alignment, realign the middle X-axis rail and check the alignment of
the top and bottom X-axis rails at the location of the failure.
• If all the joints passed testing but accessor movement failed,
manually move the accessor down the aisle in each direction to
locate any places where motion of the accessor is not smooth or is
restricted. Then realign the middle X-axis rail and check the
alignment of the top and bottom X-axis rails at the location of the
failure.
See Figure 69 on page 633.

Table of Contents

Other manuals for Quantum Scalar i6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i6000 and is the answer not in the manual?

Quantum Scalar i6000 Specifications

General IconGeneral
Form FactorRack-mountable
InterfaceFibre Channel, SAS
Product TypeTape Library
CoolingRedundant cooling fans
DimensionsVaries by configuration
WeightVaries by configuration
Operating Humidity20% to 80% non-condensing
ScalabilityScalable
Drive TypesLTO
RedundancyRedundant power supplies
ManagementWeb-based management
Tape TechnologyLTO
Supported MediaLTO Ultrium 9, LTO Ultrium 8, LTO Ultrium 7, LTO Ultrium 6
Power SupplyRedundant power supplies
Non-operating Humidity5% to 95% non-condensing