Chapter 15: Maintaining Your Library
Maintenance Actions
Quantum Scalar i6000 User’s Guide 633
Figure 69 Joint Alignments
Graphical Report
Vertical Alignments
The Vertical Alignments graphical report shows the results for test of
vertical alignment of tape magazines on the drive-side and door-side of
each frame, and for vertical alignment of each I/E station.
If the graphical report shows a failed result for the drive-side or
door-side, make sure that all tape magazines are installed properly
on that side and that the calibration targets are correctly snapped
on to the magazines.