Start-up - Lubricating the machine automatically
4 - 25
830 / 07.2012 Original operating instructions
ATTENTION
After a run-in phase of approx. 100 hours and inspecting all lubrication
points, the lubrication time can be increased or decreased as needed.
Warning
Insufficient lubrication can damage the components.
Note
Observe the notes in the maintenance instructions and in the lubrica-
tion table.
1. Lock switch for adjusting the pump RPM
Factory setting: 110 revolutions
2. Click switch to set the cycle time
Factory setting: 1 hour
3. Green LED to indicate function
4. Red LED to indicate faults
5. Button to start intermediate lubrication or to reset a fault
1
2
3
4
5