8.3 Heating system
Fan not working
Fan cannot be shut off
Fan works with
decreased power
Cause Remedy
Fuse defective or loose Check the fuse seating and insert
correctly if necessary. Replace the
defective fuse. If another defect
occurs shortly, it indicates a short-
circuit or a blockage. Check the fan
for blockages or other defects and
rectify the fault.
Power supply interrupted Check the lines for loose contacts
or open circuit.
Blower motor defective Replace the fan.
Defective operating
instrument
Check the operating instrument and
replace if necessary.
Cause Remedy
Short-circuit in the cable Rectify the short-circuit, install a
new cable if necessary
Cause Remedy
Contacts dirty Clean the plug contact. Be careful
to avoid short-circuits.
Heat exchanger heavily
contaminated
Clean thoroughly and prevent
damages that could lead to
leakages.
Attention! Please observe the
safety instructions.
Air flow insufficient because
the air filter is blocked
Clean or replace the filter.