EasyManua.ls Logo

sennebogen 830 E - Overload Warning Device (Option)

sennebogen 830 E
307 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SENCON - Sennebogen Control System - Settings/Parameterization
SENCON / 01.2013
5 - 35
5.4.10 Overload warning device (option)
The overload warning device is activated at start and is equipped with
a two-stage warning tone (interval and continuous). The warning tone
can be switched off.
WARNING
No automatic shut-off at overload! Owner and machine operator are
responsible for proper operation.
Pressure load
main boom
Green: 0 % – 90 %;
Yellow: 90 % – 100 %
(warning tone interval);
Red: >100 %
(warning tone continuous);
Selection frame
Status – warning tone
Pressure load in %
The warning tone can be switched off via the quick-select button.