SENCON - Sennebogen Control System - Settings/Parameterization
SENCON / 01.2013
5 - 34
5.4.9 Manual fan reversal / reverse
Fan reversal or fan reverse is set automatically and is activated by the
system every 30 minutes.
Fan reversal can also be switched on manually. To do so, the operator
must activate the respective quick selection button (1) on the start page.
Note
Reverse can only be started once the speed of the engine is above the
minimum speed threshold and the standby time between two reverses
has finished.
Note on the Ambient Temperature Sensor (Optional)
When the ambient temperature sensor is connected, the temperature
must be between -20°C and 40°C for reversal to take place.
The symbol does not
illuminate immediately upon
actuation of the button, but
only after starting reverse.
1