Start-up - Switching the machine off
4 - 39
830 / 07.2012 Original operating instructions
4.11.2 Disconnecting the electrical system from the battery
If the machine is idle for an extended period or for long transport
distances, the electrical system must be isolated from the battery using
the mechanical battery disconnecting switch.
WARNING
Do not switch off the mechanical battery isolating switch if:
The engine is still running
Other electrical consumers are still switched on
Doing so may damage the electrical system and its systems of control.
Do not activate the battery isolating switch until one minute after
switching off the engine (data storage for the engine).
1
Turn the battery isolating switch (1) to the left (counter-clockwise)
and remove.
The electrical system is now isolated from the battery.