Troubleshooting - Heating system
8 - 7
830 / 07.2012
Original operating instructions
System cools
intermittently
8.3.2 System extremely loud
System extremely loud
Moisture in the system – Empty the air conditioning system,
replace the collector drier, evacuate
and fill (service engineer).
Collector drier saturated – Empty the air conditioning system,
replace the collector drier, evacuate
and fill (service engineer).
Cause Remedy
Cause Remedy
Line break, faulty ground
connection or loose
contacts in the solenoid coil
of the compressor
– Check the lines, repair or replace.
Blower motor defective – Replace the fan.
Cause Remedy
V-belt loose or worn
excessively
– Tighten or replace the V-belt.
Coupling loud – Repair the coupling.
The holder for the
compressor is loose or the
internal components of the
compressor are worn
– Repair the holder; replace the
compressor.
Excessive wear on the
blower motor
– Replace the fan.