EasyManua.ls Logo

sennebogen 830 E - Page 291

sennebogen 830 E
307 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting - Heating system
8 - 5
830 / 07.2012
Original operating instructions
No heat or insufficient
heating power
Water escaping from the
unit
Air flaps can no longer
be adjusted
Cause Remedy
Water intake temperature
too low
Wait until the vehicle engine is
warm
Engine thermostat defective Replace the thermostat
Heat exchanger fins dirty Check the heat exchanger and
clean if necessary
Water lines kinked or
squashed
Rectify the cause of the fault or run
the hose properly.
Water pump pressure too
low
Coolant is not flowing through the
heat exchanger.
Air flow insufficient because
the air filter is blocked
Clean or replace the filter.
Resistor defective Replace the resistor
Climate control defective Check and replace if necessary.
Cause Remedy
Hose connection
loose
Check the hoses and tighten the
hose clips
Water hose damaged Run and connect a new hose
Heat exchanger damaged Install an original replacement part
and connect.
Attention! Observe the safety
instructions.
Cause Remedy
Servomotor defective Replace the servomotor
Foreign object blocking flap Check the flap, remove the foreign
object.
Flap deformed Check the flap and straighten if
necessary.
Flap mount defective Check the flap mount and replace if
necessary.
Control system defective Check the control system and
replace if necessary.

Table of Contents